58.8V 10A Charger Specification
The 58.8V 10A Charger is designed to provide efficient and reliable charging for 16 strings Lithium iron phosphate batteries. With its robust design and comprehensive safety features, this charger ensures optimal performance and longevity of the battery packs.
Specification | Details |
---|---|
Model | AP-PF600CH05880100 |
Input Voltage Range | 100~240Vac |
Output Voltage | 58.8Vdc |
Output Current | 10A |
Stable Voltage Accuracy | ±0.3V |
Operating Temperature | -20~+45°C |
Storage Temperature | -40~80°C |
Relative Humidity | 5%-95% |
Altitude | ≤2000m |
Cooling Method | Fan Cooling |
Output Power | 588W |
Rated Input Voltage | 100~240Vac |
Output Voltage | 58.8±0.3V |
Output Current | 10±5% A |
CC to CV Voltage | ≥57.5V |
Turn Lamp Current | 750±200 mA |
Reverse Irrigation Current | ≤1 mA |
Efficiency | ≥92% |
Output Residual Voltage | ≤36V |
Voltage and Current Regulation Mode | CAN (per communication protocol) |
Ripple & Noise | ≤500 mVp-p |
Life Time | ≥3 years |
Safety Certification | CCC, TUV, UL, CE |
Leakage Current | <3.5mA |
EMC Requirements | Class B |
Environmental Test Requirements | High/Low Temperature, Vibration, Shock |
Mechanical Characteristics | 215×100×54 mm |
Connector Definition | AC Input: L, PE, N / DC Output: DC+, DC- / Communication Control: CAN_H, CAN_L, COMMU_GND |
Key Features
- Fan Cooling System for efficient heat dissipation.
- Comprehensive protection features including reverse polarity, short circuit, overvoltage, and overcurrent protection.
- Designed with strict adherence to safety regulations.
- High efficiency and low residual voltage for optimal charging performance.
- Robust operation within a wide range of environmental conditions.
- CAN communication protocol支持的电压和电流调节模式
Applications
- Electric Vehicles: Suitable for charging lithium-ion batteries in electric scooters, bikes, and cars.
- Energy Storage Systems: Ideal for charging batteries in renewable energy storage solutions.
- Industrial Applications: Can be used in various industrial settings where high-capacity lithium-ion batteries are employed.
- Telecommunications: For charging backup batteries in telecom equipment.
- Medical Devices: Compatible with charging needs for portable medical devices with lithium-ion batteries.